TorsionLine torsion testing machine from 20 to 500 Nm

TorsionLine testing machines with maintenance-free AC servo drives are designed for single-axis torsion tests under weight loading. The torque range is 20 Nm to 2,000 Nm. The torsion axis on the TorsionLine testing machine is positioned horizontally.

TorsionLine TL1000 materials testing machine

Significant Advantages and Features

Description

Maximum stiffness ensures very accurate high rotation angle measurement resolution over the entire torque range, while high resolution allows excellent repeat accuracy to be achieved.

TorsionLine testing machines are equipped with an electrically interlocked safety device. Testing can only begin if the device is in the closed position.

testControl measurement and control electronics are used for torsion testing.

Principal areas of application for TorsionLine

  • Plastics
  • Metallic materials, for example, reverse torsion test on wire, EN 2002-13
  • Medical engineering products, for example, metal bone-screws, ISO 6475
  • Fasteners and connectors
  • Bolts/screws
  • Composites
  • Drive shafts
  • Motor bearings

Advantages & features

  • Maximum stiffness ensures very accurate high rotation angle measurement resolution over the whole torque range.
  • High resolution of high rotation angle measurement resolution
  • Use of maintenance-free AC servo drives
  • Operation with standard PC or laptop (no additional interface card required) and testXpert® II testing software
  • Designed for production, quality assurance, and research and development
  • Maximum flexibility in handling and operation thanks to state-of-the-art software control
  • Safety device with electrical interlock (CE compliant)
  • Zwick's comprehensive range of optional accessories

Technical Overview

20 Nm/200 Nm/500 Nm

Type

TL 020

TL 200

TL 500

Item No.

623679

623678

631049

Load frame

Grip-to-grip separation with universal flanges (without specimen grip)

Max. 680

max. 680

max. 680

mm

Torque (left/right)

20

200

500

Nm

Diameter of specimen/specimen holder

max. 200

Max. 200

max. 200

mm

Finish

RAL 7011 and RAL 7038

RAL 7011 and RAL 7038

RAL 7011 and RAL 7038

Ambient temperature

+10 to +35

+10 to +35

+10 to +35

°C

Relative humidity (non-condensing)

20 to 90

20 to 90

20 to 90

%

Noise level

70

70

70

dB (A)

Torsion inherent stiffness

> 1000

> 1000

> 1000

Nm/°

Axial frictional force when driving the carriage (without torsion load)

Approx. 4

Approx. 4

approx. 4

N

Total height with safety device

1775

1775

1775

mm

Total width with safety cover

1475

1475

1475

mm

Total depth

650

650

650

mm

Height of test axis

Adjustable

Adjustable

Adjustable

Safety device

Electrically interlocked

Electrically interlocked

Electrically interlocked

Anti-rotation device of torque transducer

Manually operated, electrically monitored

Manually operated, electrically monitored

Manually operated, electrically monitored

Weight with electronics, safety cover, torque transducer

185

188

188

kg

Grip-to-grip separation with 4-jaw chuck

Max. 510

max. 510

max. 510

mm

Drive

Rotation speed

In turns

0.0005 to 180

0.0005 to 90

0.0005 to 50

r.p.m

In degrees

0.072 to 64800

0.036 to 32400

0.036 to 18000

°/min

Angle resolution of the drive

3.29

1.89

0.92

Rotational second/minute

Positioning repeat accuracy (without reversal of direction)

at 1,000 °/min

≤20

≤10

≤10

Rotational second

Play at zero torque crossing

< 1

< 1

< 1

Rotational second

at 1,000 °/min

Connected loads

Electrical connections

230 (1 Ph/N/PE)

400 (3 Ph/N/PE)

400 (3 Ph/N/PE)

V

Power consumption

2.2

5

5

kVA

Frequency

50/60

50/60

50/60

Hz

1000 Nm/2000 Nm

Type

TL 1000

TL 2000

Item no.

631068

630180

Load frame

Finish

RAL 7011 and RAL 7038

RAL 7011 and RAL 7038

Torque (left/right)

1000

2000

Nm

Ambient temperature

+10 to +35

+10 to +35

°C

Relative humidity (non-condensing)

20 to 90

20 to 90

%

Noise level

62

62

dB (A)

Torsion inherent stiffness

> 11,500

> 11,500

Nm/°

Total height with safety device

1650

1650

mm

Total width with safety cover

2580

2580

mm

Total depth

843

843

mm

Height of test axis, from the floor

958

958

mm

Safety device

Electrically interlocked

Electrically interlocked

Weight with electronics, safety cover, torque transducer

1400

1400

kg

Grip-to-grip separation with face plate, without specimen holder

Max. 1000

Max. 1000

mm

Diameter of specimen/specimen holder

Max. 600

max. 600

mm

Specimen holders

Connection to load frame (gearing, torque transducer) via the face plate:

Diameter of specimen mounting flange, drive system

400

400

mm

Drive

Rotation speed

In turns

0.0005 to 20

0.0005 to 10

r.p.m

In degrees

0.18 to 7200

0.18 to 3600

°/min

Angle resolution of the drive

0.5

0.2397

Rotational second/minute

Positioning repeat accuracy (without reversal of direction)

At 1000 °/min

≤5

≤5

Rotational second

Play at zero torque crossing

< 5

< 5

Rotational seconds

Connected loads

Electrical connections

400 (3 Ph/N/PE)

400 (3 Ph/N/PE)

V

Power consumption

5

5

kVA

Frequency

50/60

50/60

Hz

Top