ZHV30 Vickers hardness tester

The ZHV30 low-load Vickers hardness tester covers Vickers and Knoop hardness tests to ISO 6507, ISO 4545 and ASTM E384 in the test-load range from HV0.2 to HV30. For wider-ranging or automated applications, PC-controlled versions are available as semi or fully automatic systems based on the high-definition software (HD).
ZHVµ-S semi-automatic micro Vickers hardness tester

Overview of key advantages

  • Load levels with motorized load change: 0.2, 0.5, 1, 3, 5, 10, 30 (in kgf).
  • Motorized turret for changing between indenter and lenses enables automatic test sequence.
  • Turret for four lenses and one indenter eliminates risk of confusion.
  • Load application via dead-weights guarantees test-force repeatability and long-term stability.
  • Freely adjustable dwell times from 5 to 60 seconds.
  • Individual lighting setting for each lens.

Additional advantages of HD software

  • Software-controlled versions for semi to fully automatic hardness testing systems offer the following additional advantages.
  • Operation and control of hardness tester via high-definition software.
  • 1.3-megapixel USB camera.
  • Scan function (stitching) with 2.5x lens provides high-resolution overview image of specimen surface.
  • Fast, easy positioning of test points in overview image.
  • Automatic indentation measurement with lighting and shadow correction eliminates operator influence during determination of the hardness value.
  • Motorized X-Y table with 100 mm x 60 mm travel.
  • Automatic hardness traverse testing.
Semi-automatic version of ZHV30-S connected to PC with high-definition hardness testing software
ZHVµ-S semi-automatic micro Vickers hardness tester

Technical overview

Overview of different operating equipment levels of the ZHV30

Type

ZHV30-M

ZHV30-S

ZHV30-A

Test

manual

semi-automatic

fully automatic

Macro Vickers test loads

0.2 to 30

0.2 to 30

0.2 to 30

kgf

Display

line display

PC monitor[1]

PC monitor[1]

Data input

membrane keyboard

PC keyboard[1]

PC keyboard[1]

Focusing

via handwheel

via handwheel

via handwheel

Optics

integrated measuring microscope

USB camera with HD connection

USB camera with HD connection

HD software

-

ZHμ.HD-S:

ZHμ.HD-A:

automatic indentation measurement

manual hardness traverse test

scan function (stitching) provides overview image of specimen surface

Test area (height x depth)

250 x 150

250 x 150

250 x 150

mm

Dimensions (H x W x D)

850 x 300 x 650

850 x 300 x 650

850 x 300 x 650

mm

Weight

50

50

50

kg

Power supply

3A single-phase, 240/120V, switchable

3A single-phase, 240/120V, switchable

3A single-phase, 240/120V, switchable

  1. PC, monitor and keyboard included in delivery.

Including accessory box and operating manual

Accessories for ZHV30 Vickers hardness tester

X-Y tables

ZHVµ-S semi-automatic micro Vickers hardness tester

X-Y tables

Type

Dimensions
[mm]

Adjustment

Item No.

Manual X-Y table

100 x 100

manual micrometers

2111222

Manual X-Y table

100 x 100

digital micrometers

2111221

Manual X-Y table

100 x 100

manual micrometers

2111224

Manual X-Y table

100 x 100

digital micrometers

2111223

Manual single-axis table

-

manual micrometer

2111226

Manual single-axis table

-

digital micrometer

2111225

Motorized X-Y table

250 x 135

-

2111227

Motorized X-Y table

250 x 135

-

2111229

Indenter

  • Available for EVERY make and model of hardness testing machine.
  • High quality, manufactured in UK.
  • Diamonds calibrated using special machines.
  • Batch calibration of balls.
  • Optionally supplied with UKAS calibration certificate.
  • Full NADCAP compliance.
  • Manufactured in accordance with quality assurance system 17025:2005.
  • Supplied in individually marked containers.
  • Relapping where possible.
  • Measurement uncertainties included in delivery for each indenter with UKAS calibration certificate.

Objective lenses

  • Available for EVERY make and model of hardness testing machine.
  • High quality, manufactured in UK.
  • Diamonds calibrated using special machines.
  • Batch calibration of balls.
  • Optionally supplied with UKAS calibration certificate.
  • Full NADCAP compliance.
  • Manufactured in accordance with quality assurance system 17025:2005.
  • Supplied in individually marked containers.
  • Relapping where possible.
  • Measurement uncertainties included in delivery for each indenter with UKAS calibration certificate.

Specimen holders

ZHVµ-A with motorized X-Y table

  • Long service life thanks to robust and simple construction
  • Light and stiff design from powder-coated aluminum alloy
  • Base with removable loading device to increase flexibility and reduce costs for specimens with varying diameters and shapes
  • Suitable for all X-Y tables by Indentec
  • Only one pressure point facing up: level alignment of the specimen surface with the indenter and lens, parallel to the X-Y table
  • Mounting possible on a prominent point on the X-Y table

Operation

  • Available for EVERY make and model of hardness testing machine.
  • High quality, manufactured in UK.
  • Diamonds calibrated using special machines.
  • Batch calibration of balls.
  • Optionally supplied with UKAS calibration certificate.
  • Full NADCAP compliance.
  • Manufactured in accordance with quality assurance system 17025:2005.
  • Supplied in individually marked containers.
  • Relapping where possible.
  • Measurement uncertainties included in delivery for each indenter with UKAS calibration certificate.